How do I get Fire Certification?
It's simple, just keep proof of purchase, batch numbers of the products used along with site details and contact Bollom's Customer Services Department on 0191 410 6611 with the information and they will send you the relevant Certificate of Supply within 5 working days.
What fire protection rating does Bollom Broflame Ultra Basecoat achieve?
When finished with a specified Bollom Flameguard Ultra topcoat, the system is tested to BS EN 13501-1:2018, achieving Class B-s1, d0 / Class B-s2, d0. The classification depends on the surface and complete coating system used. Follow the technical data sheets for both products.
Can I apply Bollom Broflame Ultra Basecoat over existing paint?
Yes, provided the existing finish consists of no more than four coats of sound conventional decorative paint that adhere firmly to the timber. Remove loose or flaking paint and wet abrade existing gloss or eggshell finishes before application. The timber must be at least 9mm thick.
Does Bollom Broflame Ultra Basecoat need a topcoat?
Yes. It must be overcoated with Bollom Flameguard Ultra Gloss, Acrylic Eggshell or Vinyl Matt Topcoat to complete the tested fire protection system. It cannot be left as the final finish.
Can Bollom Broflame Ultra Basecoat be applied by roller or spray?
Yes. Apply by brush, roller or airless spray. When using a roller, brush over the wet coating to achieve a smooth finish. Airless spraying requires suitable equipment and the settings specified in the technical data sheet. Do not thin the paint.
How many coats are required and what is the coverage?
Apply two coats at 5m² per litre per coat. A 5-litre tin therefore covers approximately 12.5m² with both coats. Maintain the specified coverage rate, as the required coating thickness is essential to the tested fire performance.
How long should I wait between coats and before topcoating?
At 20°C, allow at least 4 hours between basecoat coats and at least 24 hours after the second coat before applying a Bollom Flameguard Ultra topcoat.